Mike Krzyzewski is really a famous coach of Dream Team. She has coached north america men's basketball team for some time, that's clinched numerous medals for his country. Following Londonfl jerseys supplyn Olympic was over, Krzyzewski told The Associated Press that this game will be his final one as national coach, a job he's held for seven years. He had left open the possibility of swomen nfl jerseystaying with the team beyond the London Games, when practice on Saturday said these will be his last Olympics.When asked if he was sure, Krzyzewski didn't hesitate before again saying, "yecheap nfl jerseys wholesales," this will be his last game "If we could win it, then it might be three major championships in a row, i always do not know when that has been done because we haven't usually won http://govoriotkrito.bg/libs/nflcn08.htmthe globe championships," Krzyzewski said. "It becomes an enormous thing for the program." Whatever, he's an awesome coach. His achievement are going to be remembered by the country.cheap nfl jerseys

CRM1塑料外壳式断路器

更新:2013-9-23 14:46:54      点击:
  • 产品品牌   
  • 产品型号   CRM1
  • 产品描述

    CRM1塑料外壳式断路器,是上海人民电气有限公司 http://www.shamandq.com 为您提供的关于CRM1塑料外壳式断路器型号,CRM1塑料外壳式断路器价格,有关CRM1塑料外壳式断路器...

产品介绍

注:1.按额定极限短路分断能力的高低分为L型(标准型)、M型(较高分断型)、H型(高分断型)。
2.手柄直接操作无代号:电动操作用P表示;转动手柄用Z表示。
3.配电用断路器无代号:保护电动机用2表示。
4.按产品极数分为三极、四极,四极产品中中性极(N极)的形式分四种:
A型:N极不安装过电流脱扣器,且N极始终接通,不与其他三极一起合分。
B型:N极不安装过电流脱扣器,且N极与其他三极一起合分(N极先合后分)。
C型:N极安装过电流脱扣器,且N极与其它三极一起合分(N极先合后分)。
D型:N极安装过电流脱扣器,且N极始终接通,不与其它三极一起合分。

 

断路器按照其额定极限短路分断能力,分为L型(标准型)、M型(较高分断型)、H型(高分断型)三种。该断路器具有体积小、分断能力、飞弧短、抗振动等特点。
断路器可垂直安装(即竖装),亦可水平安装(即横装)。

二、2.1周围空气温度
???a.周围空气温度上限不超过+40℃;
???b.周围空气温度下线不低于-5℃;
???c.周围空气温度24h内的平均值不超过+35℃;
(1)周围空气温度下限为-10℃或-25℃的工作条件,订货时用户须向制造商声明。
(2)周围空气温度上限超过+40℃或下限低于-25℃的工作条件,用户订货时必须与制造厂协商。
2.2海拔:安装地点的海拔不超过2000m;
2.3大气条件
周围空气温度为+40℃时,大气的相对湿度不超过50%,在较低的温度下可以有较高的相对湿度,例如20℃时达90%,对由于温度变化偶尔产生的凝露应采取特殊的措施。
2.4污染等级:安装地点的污染等级为3级。
2.5安装类别:断路器主电路的安装类别为Ⅲ,Inm≤800A可为Ⅳ;不接至主电路的辅助电路和控制电路的安装类别Inm≤400A为Ⅱ,Inm≥630A的为Ⅲ。
2.6安装条件:断路器应按照本厂提供的使用说明书户内单独安装或安装在配电柜中,安装面与垂直面侧倾斜度不大于5°。
2.7安装环境条件
a.安装在无显著摇动和冲击振动的地方;
b.安装在无雨雪侵袭的地方;
c.安装地方应无爆炸危险的介质,且介质中无足以腐蚀金属和破坏绝缘的气体与尘埃。


保护特性?:

脱扣器动作性能?
配电用??????????表1

?

脱扣器额定工作电流(A)

热脱扣器(基准温度40℃)

电磁脱扣器动作电流(A)

备注

1.05In(冷态)不动作时间(h)

1.30In(热态)不动作时间(h)

10<In≤63

≥1

<1

10In±20%

配电保护型
注:
1250A为
7In±20%

63<In≤100

≥2

<2

10In±20%

100<In≤1250

≥2

<2

5In±20%
7In±20%
10In±20%

注:额定电流小于160A无5In电流脱扣
保护电动机用

脱扣器额定工作
电流(A)
10≤In≤630

热脱扣器(基准温度40℃)

电磁脱扣器动作电流(A)

1.0In(冷态)不动作时间(h)

1.20In(冷态)不动作时间(h)

1.50In(冷态)不动作时间(h)

7.20In(冷态)不动作时间(h)

≥2

≤2

8min

6S<Tp≤20s

12In±20%

功率耗损?:

断路器功率损耗??????????表2?

?

型号

通电电流(A)

三极总功率损耗(W)

板前、板后接线

插入式板前接线

插入式班后接线

CRM1-63(L、M)直热型(10A~25A)

25

28

/

32

CRM1-100(L、M、H)直热型(16A~25A)

25

40

42

45

CRM1-63(L、M)间热型(32A~63A)

63

20

/

24

CRM1-100(L、M、H)间热型(32A~100A)

100

35

37

40

CRM1-225(L、M、H)

225

62

66

70

CRM1-400(L、M、H)

400

115

120

125

CRM1-630(L、M、H)

630

187

193

200

CRM1-800(L、M、H)

800

262

/

300

CRM1-1250(L、M、H)

1250

386

/

/

降容系数?:

断路器环境温度变化的降容系数??????????表3

型号

降容系数(In)

+40℃

+45℃

+50℃

+55℃

+60℃

CRM1-63

1

0.94

0.88

0.81

0.74

CRM1-100

1

0.96

0.91

0.85

0.78

CRM1-225

1

0.97

0.94

0.90

0.86

CRM1-400

1

0.95

0.89

0.82

0.75

CRM1-630

1

0.94

0.88

0.82

0.76

CRM1-800

1

0.94

0.87

0.80

0.72

CRM1-1250

1

0.92

0.85

0.79

0.70

注:以上降容系数均在通于壳架额定电流下测得

型号

壳架等级额定电流Inm(A)

额定电流In(A)

额定工作电压Ue(V)

额定绝缘电压Ui(V)

极数

额定极限短路分断能力级别

额定极限短路分断能力Icu(kA)

额定运行短路分断能力Ics(kA)

操作性能
(次)

操作性能
(次)

飞弧距离(mm)

AC
690V

AC
400V

AC
690V

AC
400V

通电

不通电

L

W

H

CRM1-63

63

10、16、20、25、32、40、50、63

AC?400

AC?500

3

L

25

18

4500

8500

135

78

73.5

≤50

3

M

50

35

81.5

4

103

CRM1-100

100

16、20、25、32、40、50、63、80、100

AC?400

AC?800

3

L

35

22

3000

7000

150

92

68

≤50

AC?690
AC?400

3

M

10

50

10

35

86

AC?400

4

50

35

122

AC?400

3

H

85

50

92

CRM1-225

225

100、125、140、160、180、200、225

AC?400

AC?800

3

L

35

22

2500

6500

165

107

86

≤50

AC?690
AC?400

3

M

10

50

10

35

103

AC?400

4

50

35

142

AC?400

3

H

85

50

107

CRM1-400

400

225、250、315、350、400

AC?400

AC?800

3

L

50

35

1500

4000

257

150

106.5

≤50

AC?690
AC?400

3

M

15

65

15

42

AC?400

4

65

42

198

AC?400

3

H

100

65

150

CRM1-630

630

400
500
600

AC?400

AC?800

3

L

50

35

1500

4000

270

182

110

≤100

AC?690
AC?400

3

M

15

65

15

42

AC?400

4

65

42

240

AC?400

3

H

100

65

182

CRM1-800

800

630
700
800

AC?690
AC?400

AC?800

3

M

20

65

20

42

1000

2500

280

210

115.5

≤100

AC?400

4

280

3

H

100

65

210

CRM1-1250

1250

630、700、
、800、1000
1250

AC?400
AC?690

AC?800

3

M

20

65

18

32.5

500

2500

330

210

137

≤120

?

附件名称

不带附件

报警触头

分励脱扣器

辅助触头

欠电压脱扣器

分励脱扣器辅助触头

分励脱扣器欠电压脱扣器

二组辅助触头

辅助触头欠电压脱扣器

分励脱扣器报警触头

辅助触头
报警触头

欠电压脱扣器报警触头

分励脱扣器辅助触头报警触头

分励脱扣器欠电压脱扣器报警触头

二组辅助触头报警触头

辅助触头欠电压脱扣器报警触头

脱扣器方式

瞬间代号

200

208

210

220

230

240

250

260

270

218

228

238

248

258

268

278

复式代号

300

308

310

320

330

340

350

360

370

318

328

338

348

358

368

378

?

注:
1200:表示仅有电磁脱扣器的断路器;300:表示带有热动—电磁脱扣器的断路器;000:表示不带过流脱扣器的断路器(隔离开关);
2、对CRM1-100225二极产品只有210310220320230330;对CRM1-63100225四极断路器,N极为A型和D型时无240340360260268368
3、对CRM1-400CRM1-630CRM1-800其中248348278378规格中辅助触头为一对触头(即一常开、一常闭),268368规格中的辅助触头为三对触头(即三常开、三常闭);其余规格辅助触头数量CRM1-400及以上为二组,CRM1-225及以下为一组。
4、对CRM1-63CRM1-100CRM1-160CRM1-225CRM1-250其中220320240340270370规格中辅助触头可供二对触头(即二常开、二常闭),260360可供三对触头(即三常开、三常闭),但订货时需注明。

使用和维护

5.1?断路器应垂直安装,安装前应检查断路器名牌上所列的技术参数是否符合使用要求。

5.2?板前接线的断路器允许安装在金属板或金属支架上,但板后接线的断路器一般安装在绝缘底板上。

5.3?本系列断路器飞弧距离为200mm,断路器的进线端应用绝缘材料包扎200mm或用绝缘板把相间隔开。

5.4?断路器在正常工作时不需要维护和修理,但在受到较大的故障电流后,必须进行仔细检查,查看触头是否良好,并清除断路器内部的尘埃及金属粒子,在设备停机维修时,可打开断路器,在传动的轴销处加钟表油。

九、订货须知

用户在订货时,须将断路器的型号、规格、分断能力、写清除,采用欠电压或分励脱扣器应写明交流电压值。

例:CRM1-225L/3330板后接线,(板前接线可不写)

????欠电压脱扣交流380V,额定电流225A

更多产品